Audio Signal Voltage Tester

Mondo Technology Updated on 2024-01-19

According to the standard: GB49431-2022 p. e1. Classification and safety protection of audio signal electrical energy source;

1. Overview

This device is a precision level measuring instrument, which has two characteristics: accurate measurement and frequency digital display. Its frequency range is 15Hz 20kHz and the level measurement range is 40dB -110dB (or 100V 3 V). This equipment is combined with the corresponding low-frequency oscillator, and can be used as a measurement of important parameters of various equipment such as wired carrier communication, satellite communication ground station, radio communication terminal equipment, broadcast transmission system, television sound system, electroacoustic equipment and power system.

It can also be used as a signal harmonic analysis in the low frequency range, so it is also called a waveform analyzer.

Second, the main technical parameters

1. Broadband measurement.

Frequency range: 15Hz 20kHz

Measuring range: -80dB 40dB (10dB conversion per step) or 100 V 100V

Minimum measurable level (voltage): 90dB (30 V).

2. Frequency selection measurement.

Frequency range: 30Hz 20kHz

Measuring range: -80dB 40dB (10dB conversion per step) or 100 V 100V

Minimum measurable level (voltage): 90dB (30 V).

Frequency error: 2 10-5 8hz

Frequency resolution: 1Hz

3. Zero level error: 0. after level correction2db

4. Level switch shift error: 02db

5. Meter scale error: 06db

6. Input balance attenuation: 40db

7. Input impedance: balance 600 5%.

High impedance 10k

8. Frequency response.

Broadband 15hz 20khz 04db

20hz~20khz±0.2db

Frequency selectivity: 60hz 20khz 02db

9. Noise in the machine.

Broadband: 100db

Frequency selection: 100dB (50Hz AC power supply is allowed to cause interference noise caused by the second and third harmonics -110dB).

10. Frequency selectivity: 30Hz 20kHz, 60Hz 20kHz

Passband width: a=3db narrowband 6hz wideband 20hz

Stop band width: A 50dB narrowband FM 50Hz

A 40dB wideband FM 50Hz

11. Residual distortion.

60Hz 200Hz: When the sensitivity is increased by 40dB, the second and third harmonics attenuate by 50dB

200Hz 20kHz: When the sensitivity is increased by 50dB, the second and third harmonics attenuate 60dB

12. Level stability.

After the instrument is warmed up for 30 minutes, the level changes for 3 hours of continuous operation:

Corrected 02db

13. When the AC power supply changes by 10% at 50Hz 220V, the level changes by 01db

14. Coordinate the system.

Frequency range: f+100kHz

Level: Approx. -8dB 10dB 75

Additional error between unified and non-unified modulation: 04db

15. Dimensions: 440mm 360mm 144mm

16. Mass: about 13kg

17. Power consumption: about 12W