Fagor FAGOR CNC system maintenance, please rest assured

Mondo Technology Updated on 2024-01-28

In the field of CNC machine tools, Fagor CNC systems are favored for their excellent performance and stability. However, once there is a power-on spark screen failure, the repair process can be a problem for many technicians. This article will introduce in detail the steps and precautions for the repair of the slap screen on the Fagor CNC system, to help you quickly solve the fault and restore the normal operation of the machine tool.

First, the fault phenomenon.

The spark screen on the Fagor CNC system is a common fault phenomenon, which is usually manifested as stripes of various colors, garbled characters or no display at all. This failure can have a serious impact on the normal operation of the machine and therefore requires timely repairs.

Second, the cause of the failure.

The power-on splash screen fault may be caused by the following reasons:

1.Faulty display: There may be a problem with the display itself, such as damaged cables, connectors, or display panels on the display.

2.Power failure: There may be problems with the power supply part of the CNC system, such as a faulty power module or poor contact of the power cord.

3.Control system failure: There may be a problem with the control system part of the CNC system, such as CPU, memory, or hard disk failure.

4.External interference: Electromagnetic interference around the machine can cause the power-on spark screen to fail.

3. Maintenance steps.

1.Check the power supply: First check whether the power supply of the CNC system is normal. You can observe whether the power indicator lights up and whether the power cord is in good contact. If the power supply is normal, proceed to the next step.

2.Check the display: Check the display for physical damage, such as cracks, detachment, or discoloration. If there is physical damage, it needs to be replaced or repaired. If there is no physical damage, proceed to the next step.

3.Check the control part: Open the casing of the CNC system and check whether the components of the control part are obviously burned or damaged. If there is, the corresponding component needs to be replaced. If not, proceed to the next step.

4.Check for external interference: If there is a source of electromagnetic interference around the machine, you need to take steps to eliminate it, such as adding a shield or moving away from the source of interference.

5.Software debugging: If the above steps do not solve the problem, it may be caused by a software problem. At this point, you need to debug the software to check the program for errors or conflicts. If there is, you will need to modify the program and re-upload it to the CNC system.

6.Back up data: During the repair process, it is recommended to back up important data in the CNC system to prevent data loss or damage. This data includes programs, parameter settings, tool compensation, and much more. Backing up data ensures that important information is not lost during the repair process, reducing losses and recovery time.

7.Maintenance records: During the maintenance process, it is recommended to record the maintenance records, including the maintenance time, maintenance steps, replaced components, etc. Repair records can help technicians better understand the repair process and where the problem lies, so that they can better carry out subsequent maintenance and upkeep work.

4. Precautions.

1.During the repair process, it is necessary to turn off the power and operate with appropriate tools to avoid greater damage to the CNC system.

2.When replacing a component, it is necessary to confirm whether the model and specification of the replaced component are correct to avoid incompatibility.

3.When debugging the software, you need to carefully check the errors or conflicts in the program to avoid unresolved power-on screen faults due to software problems.

4.During the maintenance process, it is necessary to maintain a clean and tidy working environment to avoid failure or damage to the CNC system caused by dust or other impurities.

5.After the repair is completed, testing and verification are required to ensure that the CNC system can operate normally and solve the problem of the power on spark screen failure.