What should I do if the floor heating pressure gauge is 0?

Mondo Home Updated on 2024-01-31

With the development of science and technology and the improvement of people's living standards, home heating equipment is also constantly upgrading. As a comfortable and energy-saving heating method, floor heating is becoming more and more popular among people. However, during use, some problems may be encountered, such as the floor heating pressure gauge showing 0. So, what should you do if the floor heating pressure gauge is 0?This article will introduce it to you in detail.

1. The reason why the floor heating pressure gauge is 0.

1.System leakage: The water in the underfloor heating system is recycled, and if there is a leak in the system, the water pressure will decrease, causing the pressure gauge to show 0.

2.Pump failure: The water pump in the underfloor heating system is responsible for delivering hot water to the various rooms, and if the pump fails and does not work properly, it will cause the water pressure to drop.

3.Pipe blockage: Impurities, sediments, etc. in floor heating pipes may cause pipe blockage, affecting the smooth flow of water, resulting in a decrease in water pressure.

4.Expansion Tank Problem: The expansion tank is responsible for storing excess water in the system and if there is a problem with the expansion tank, it will also affect the water pressure.

Second, the solution of the floor heating pressure gauge is 0.

1.Check the system for water leakage: first turn off the power of the floor heating system, and then check the pipes, valves and other parts one by one for water leakage. If a water leak is found, the relevant parts should be repaired or replaced in time.

2.Check the water pump: Check whether the water pump is working properly, if the water pump is found to be faulty, it should be repaired or replaced in time.

3.Cleaning the pipeline: If the pipe is found to be blocked, it can be cleaned with a high-pressure water gun or chemical cleaning agent to restore the smooth flow of water.

4.Check the expansion tank: Check whether the expansion tank is operating normally, and if a problem is found, it should be repaired or replaced in time.

5.Refill: After eliminating the above problems, the underfloor heating system needs to be refilled until the pressure gauge shows normal water pressure. Pay attention to the process of water filling to be done slowly to avoid damage to the system due to excessive water pressure.

3. Preventive measures for the floor heating pressure gauge to be 0.

1.Regular inspection: Regularly inspect the floor heating system, find problems and deal with them in time, so as to avoid small problems from turning into big problems.

2.Choose high-quality materials: When installing a floor heating system, it is necessary to choose high-quality pipes, valves and other materials to ensure the stable operation of the system.

3.Reasonable use: When using the floor heating system, it is necessary to avoid frequent switching of the power supply to avoid damage to the system.

4.Professional maintenance: Underfloor heating systems require regular professional maintenance to ensure the proper functioning of the system.

The above are some solutions to the floor heating pressure gauge is 0, I hope it will help you.