Data Definitions( data define )
InSystem settingsData DefinitionsThe page lists all of themManagement featuresprojectorManagement featuresMold tryoutThe content of the page that can be defined or set by the user. Different pagination has different properties and correspondenceManagement featuresprojectorManagement featuresMold tryoutThe content of the page.
System Settings > Data Definition.
ClassificationQuality dashboard) (classification (quality dashboard))
New categories such as industry, products, and plastic parts are addedKnowledge baseFilters for the page. In addition to being used as a filter condition, the newly added category can also be included as a new itemManagement featuresprojectCreate a projectTags for the page.
Users can click on itEdit keyorDelete the keyto edit or delete an existing category;In addition, if the user wantsReplace the text in the title block(Industry, Products, and Plastic Parts) can also be clickedEdit the categorybutton to change to other text, note that the number of words in the title text cannot be changedexceededcharacters, which is not supported eitherSpecial symbolsIn addition, users can also click on demandEdit the categoryunder the windowNew levelsbutton to increase the classification level, note that it can be expanded to a maximum of 5 levels.
However, if the user deletes the name of the top-level category due to demand, all the operation functions related to the classification will be unavailable, in the upper right corner of the pageCreateIt will also be grayed out and will only show the retained Quality Dashboard data. On the other hand, if there is no hierarchy at all, all items will be automatically listed in the Knowledge Base page, and the Category Crawler will be removed, howeverSearcher, History, Filter, Outputcsvand other features will be retained.
Note: If there is no categorization, this page will only display the retained quality dashboard data (if any).In addition, a message will be displayed: "There are no categories at this time, so the quality dashboard will belong to each project".
System Settings > Data Definition > Edit Classification.
Knowledge Base > Classification Filter.
Manage features > Projects > Create Projects > New Project tabs.
System Settings > Data Definition > Classification > Create Classification Entry.
System Settings > Data Definition > Classification > No Classification Data.
In System Settings> Data Definition > Categorized Items:
industryproductsPlastic parts: Select a category option for an individual field, or click at the bottom of the menu if the option does not appear in the drop-down menuNew industriesproductsPlastic partsEnter a name for the new option and clickNew, that is, done. Note: Symbols for invalid characters cannot be entered;In addition, if you do not enter any information, you will not be able to click Add New.
Edit the category
Click this button to edit the default category name. Click the edit key in the field where you want to change the category name to change itIt should be noted that it cannot be enteredSpecial characters, and you can't enter more than thatThe name of the character . When you want to delete a category name, click the delete button in the field to delete the categoryWhen a category is deleted and the data about the category is automatically assigned to the next level, a prompt will automatically pop up asking the user if they want to keep itQuality dashboard;If the system determines that the storage space is sufficient, the data can be saved. In addition, when a quality dashboard with a duplicate name is encountered after the merge, the system automatically retains itprojectThe most quantity (most used) quality dashboard data.
Note
If the user wants to add a tier, click itNew levelsbutton to add a new category name.
Only the lowest-level category name can be deleted.
New levels
Click in the Edit Category windowNew levelsbutton to add a classification level;Note that you can only add up to 5 layers, and you need to enter a category name to successfully add a new layer. The same entry rules do not allow special characters to be entered, nor can they be exceededcharactersAfter the new addition is successful, the default option for this level is ".Undefined
Status
This shows the status of the category:EnabledwithDeactivated
Enabled: Enabled categories can be selected from the following screens.
Knowledge basePage.
Management featuresprojectCreate a projectPage.
Deactivated: Disabled categories cannot be selected on the following screens.
Knowledge basePage.
Management featuresprojectCreate a projectPage.
In addition, users can also open it by clicking on the category columncae( Calculator Aided Engineering ) orMold tryoutQuality dashboardSettings dialog box.
Click on the + symbol to do socaeormold tryoutCreate a quality dashboard for a new scope. Click on the edit key symbol to edit or ** station to delete the quality dashboard. Both settings are made in a pop-up dialog.
NoteWhen the item is selected from the drop-down menuUser-defined definition, it will appearOnly the user acknowledgement status is providedchecks the field.
System Setup > Data Definition > Classification > Create a quality dashboard for CAE or tryout.
System Setup > Data Definition > Classification > Create Quality Dashboard > User-defined.
The system sets > data definitions> classifications> creates a quality dashboard for CAEs or tryouts (when CAEs are selected).
The system sets > data definitions> classifications> creates a quality dashboard for CAEs or tryouts (when tryouts are selected).
In System Settings> Data Settings> Classification> Create a CAE or Tryout Quality Dashboard Project:
Category
When you create or edit a new quality dashboard, the decision dashboard classification iscaeStillMold tryout
Note: IfMold tryoutoption is selectedNumeric itemsMeasurementsThe field appears. ClickMeasurements, the object after that becomes *Inspection itemsNumeric only
units
Units of measurement. UnlessprojectYesUser-definedOtherwise, it cannot be changed.
project
When you create a new quality dashboard, select the one you want to evaluateName the project。When editing an existing quality dashboard, select a new name item to update the settings.
NoteCategoryThe field must be selected first, otherwise nothing will appear in the drop-down menu.
When CAE is selected in the Category field, the following objects appear in the drop-down menu:
Pressure drop of the plastic part
This refers to the pressure drop at the front end of the fluid during the molding process.
Runner pressure loss
This refers to the inevitable events that occur in every piping system due to friction, height changes, and turbulence caused by sudden changes in direction.
Maximum gate pressure
This refers to the maximum pressure of the gate during the filling process.
Maximum clamping force
This refers to the maximum force exerted by the clamping unit of the injection molding machine on the mold. In order for the mold to remain closed, the clamping force must be countered by the separation force caused by the molten plastic injected into the mold.
Cycle time
This refers to the total time spent to complete all the stages of the injection molding cycle.
Total deformation
This refers to the displacement vector relative to the coordinates of the model, taking into account all components in the x, y, and z directions on Cartesian coordinates.
xThe amount of shaft deformation
This refers to the change in position in the x-direction.
yThe amount of shaft deformation
This refers to the change in position in the y-direction.
zThe amount of shaft deformation
This refers to the change in position in the z-direction.
User-defined(cae)
This refers to user-defined assessment items. Also, when this item is selected, thenOnly the user acknowledgement status is providedThe checkbox appears in the scope state.
Note
User-defined quality dashboards will be available inManagement featuresprojectReview> moldex3d >MoreSummary of the groupReview.
If "" is checkedOnly the user acknowledgement status is providedYou don't need to enter the values of each range to send itIn additionManagement featuresprojectReview> moldex3d >MoreSummary of the groupReview, and when you click the edit key for the quality dashboard, the scoreable status isPoor, acceptable, excellent.
When selected in the * category fieldMold tryout, the following objects will appear in the drop-down menu:
The actual value of the maximum clamping force( ton/ kn )
This refers to the actual maximum force exerted by the clamping unit of the injection molding machine on the mold. The unit of measurement can be tonnes or kilonewtons (kn).
The actual value of the maximum injection pressure(mpa/ bar/ psi)
This refers to the actual maximum force with which the molten plastic resin is pushed into the mold cavity. The unit of measurement can be megapascals (mpa), bar (bar), or pound-force per square inch (psi).
Cycle time
This refers to the total time spent to complete all the stages of the injection molding cycle.
User-defined( mold tryout )
This displays user-defined items. In additionOnly the user acknowledgement status is providedThe checkbox will appear inScope statusMiddle.
Note
User-defined quality dashboards will be available inManagement featuresprojectMold tryoutMore.
Tick "Only the user acknowledgement status is providedYou don't need to enter the values of each range to send itIn additionManagement featuresprojectMold tryoutMore, and when you click the edit key for the quality dashboard, the scoreable status isPoor, acceptable, excellent.
Scoping
When you create a new assessment dashboard, first select the half pie chart you want to use. Once the selection is completeTarget rangeThe field appears in the lower half of the window. When you want to edit an existing assessment dashboard, reselect a different half of the pie chart to change the settings.
The scope of user customization is open
Select this option to apply the self-defined scoping.
Note: This is displayed when checkedManagement featuresprojectReviewinformationQuality dashboard
Target range
When you create a new assessment dashboard, you'll want to define it after you've selected the appropriate half pie chartExcellent and acceptableIf needed, poorThe range of values. This field is only available inScopingIt will not appear until the selection is complete. When you want to edit an existing evaluation dashboard, enter a different range of values to change the settings.
Note: The user can only enter a numeric value.