How to collect the flow signal in the digital control system? Detailed explanation of the method and

Mondo Technology Updated on 2024-02-29

In the digital control system, the acquisition of flow signal is a crucial link, which is directly related to the control accuracy and response speed of the system to the fluid flow state. In the following, I combine professional knowledge and practical experience to make a detailed analysis of the flow signal acquisition method in the digital control system.

The flow signal reflects the flow state of the fluid in the pipeline, including information such as flow rate and flow velocity distribution. In the digital control system, through the real-time acquisition and processing of flow signals, the precise control of the fluid flow state can be realized, so as to meet the process requirements, improve production efficiency and product quality.

The acquisition of flow signals is also the basis for closed-loop control, and the control strategy of the system can be adjusted in real time through the analysis of feedback signals to ensure the stability and reliability of the system.

1.Differential pressure flow meter

A differential pressure flow meter is a common flow meter that calculates the flow rate by measuring the differential pressure generated by a fluid in a pipe. Differential pressure flowmeter has the advantages of simple structure, wide measurement range and good stability, so it has been widely used in industrial production. However, it also has some drawbacks, such as susceptibility to changes in fluid density and viscosity, and the need for regular calibration.

2.Vortex flowmeter

Vortex flowmeters measure flow rates using the vortex effect generated by fluids in vortex sensors. It has high measurement accuracy and stability, and is suitable for a variety of fluid media and measurement environments. However, the installation requirements of vortex flowmeters are high, and there are certain requirements for the stability of fluid flow.

3.Electromagnetic flowmeter

Electromagnetic flowmeters are based on Faraday's law of electromagnetic induction for flow measurement. It has the advantages of accurate measurement, fast response speed and wide application range, and is especially suitable for fluid media with high conductivity. However, electromagnetic flowmeters are more expensive and sensitive to impurities and bubbles in fluids.

4.Ultrasonic flow meter

Ultrasonic flow meters measure flow using the relationship between the speed at which ultrasonic waves propagate through a fluid and the flow rate. It has the advantages of non-contact measurement, no interference with the fluid, and high measurement accuracy. However, the installation and maintenance requirements of ultrasonic flowmeters are high, and they are greatly affected by factors such as fluid temperature and pressure.

1.Determine the flow measurement point

Before proceeding with the flow signal acquisition, it is first necessary to determine the appropriate flow measurement point. The selection of the measuring point should take into account factors such as the flow state of the fluid, the layout of the pipes, and the measurement requirements. The measurement point should be selected in an area where the fluid flow is stable and there are no large number of eddies and vortices.

2.Choose the right flow meter

According to the actual situation of the measuring point and the measurement requirements, select the appropriate flow meter type. In the selection process, the measurement range, accuracy, stability, response time and other factors of the flowmeter should be comprehensively considered, and the influence of the characteristics of the fluid medium (such as temperature, pressure, conductivity, etc.) on the flowmeter should be considered.

3.Install a flow meter

In accordance with the installation requirements of the flow meter, it is installed at the selected measuring point. During the installation process, attention should be paid to ensuring that the length of the measuring pipe section of the flowmeter and the upstream and downstream straight pipe sections meet the specified requirements, and avoid installing elbows, valves and other components that may produce eddy currents and interfere with the flow.

4.Connect the signal cable

Connect the signal line of the flow meter to the data acquisition system or control system. During the connection process, attention should be paid to the shielding and grounding of the signal line to reduce the impact of external interference on the measurement accuracy.

5.Commissioning and calibration

After the installation of the flow meter and the connection of the signal cables, commissioning and calibration work is required. The accuracy of the flow signal is ensured by adjusting the parameters and calibration curves of the flow meter so that the measurement results are consistent with the actual flow value.

6.Real-time acquisition and processing

In the digital control system, the output signal of the flowmeter is collected in real time through the data acquisition module. The collected signal is pre-processed (such as filtering, amplification, etc.) and then input to the digital control system for processing and analysis. During the processing process, the flow signal can be further processed (such as integration, differentiation, etc.) as needed to meet the requirements of the control system.

1.Ensure a stable flow of fluid at the measuring point and avoid eddy currents and swirls.

2.Select the appropriate type of flow meter according to the characteristics of the fluid medium, and pay attention to the measurement range and accuracy requirements of the flow meter.

3.When installing the flow meter, the manufacturer's installation requirements should be followed to ensure that the length of the measuring pipe section and the upstream and downstream straight pipe sections meet the requirements.

4.When connecting the signal line, attention should be paid to the shielding and grounding of the signal line to reduce the impact of external interference on the measurement accuracy.

5.The flow meter is regularly debugged and calibrated to ensure the accuracy and stability of its measurement results.

6.In the digital control system, the collected flow signals should be preprocessed and analyzed as needed to meet the requirements of the control system.

In summary, the acquisition of flow signals is a crucial part of the digital control system. Through a detailed analysis of the different acquisition methods and procedures, we can better understand and apply this knowledge to our work. We should also pay attention to the advantages and disadvantages of various acquisition methods and the precautions in practical application to ensure the accuracy and reliability of flow signal acquisition.