Requirements for the construction of medical lead door walls

Mondo Home Updated on 2024-02-05

During this time, I checked my friend's reply and found that many friends are not very clear about the construction requirements of the medical lead door wall.

The construction requirements for medical lead door walls mainly refer to a series of regulations and requirements that need to be complied with when installing lead door walls in medical places. The following is a brief introduction to the construction requirements of medical lead door walls from relevant aspects, and gradually expand the relevant content.

1. Material selection of medical lead door wall: High-quality lead material with high density and high lead content should be selected for medical lead door wall to ensure that the radiation protection performance meets the standard requirements.

2.Installation requirements for medical lead door walls: When installing medical lead door walls, it is necessary to install them correctly in accordance with the design requirements, and attention should be paid to ensuring that the structure is firm and reliable to ensure that the protective performance is intact.

3.Opening and closing methods of lead doors: The opening and closing methods of medical lead doors should be convenient and fast, flexible in operation, and at the same time ensure that the door can be effectively sealed when closed to avoid radiation leakage.

4.The connection between the lead door wall and the surrounding structure: The connection between the medical lead door wall and the surrounding structure should be tight and firm to avoid the generation of voids and gaps to ensure that radioactive substances will not leak through the connection.

5.Sealing performance of the door leaf: The radiation leakage of the door leaf of the medical lead door should meet the requirements of the relevant standards, the sealing performance must be good, and there should be no obvious gap between the door leaf and the door frame to ensure the radiation protection effect.

6.Fire performance of the door leaf: The door leaf of the medical lead door also needs to have a certain fire performance to ensure the strict implementation of fire protection requirements and avoid injury to personnel and equipment in the event of a fire.

7.Maintenance and cleaning of lead door walls: Medical lead door walls should be regularly maintained and cleaned to ensure their normal use and long-term maintenance of protective performance.

Other factors need to be considered in the construction of medical lead door walls, such as safety protection during construction, equipment and use of radiation protection equipment, professional skills and training of the construction team, etc. A detailed understanding of these related contents will help you better understand the importance of the construction requirements and the correctness of the implementation of the requirements for the construction of medical lead door walls.

Related Pages