For an article to understand the key points of the construction of the lead door in the DR room, many people do not know much, here is an introduction related to this for everyone, interested family and friends can read and collect it.
The key points of the construction of the lead door of the DR room refer to the installation methods and precautions of the lead door that need special attention and key consideration in the process of the construction of the DR room (radiation room). The following is a brief introduction to the construction of the lead door of the DR room:
First, the installation of the lead door:
1. Determine the location of the lead door: determine the specific location of the lead door according to the design drawings and layout requirements of the radiation room.
2.Size requirements for lead doors: Ensure that the size of the lead door meets the requirements for radiation protection, usually made of lead plates with a thickness of more than 2 mm.
3.Construction of lead door frame: According to the size and requirements of the lead door, build the lead door frame first to ensure the stability and firmness of the frame.
4.Installation of the lead door: Place the lead door on the lead door frame and make sure there is no gap between the door and the frame. At the same time, it is necessary to ensure that the opening and closing of the lead door is flexible and smooth.
Second, the precautions for the lead door:
1. Tightness of the lead door: During the installation process, it is necessary to pay attention to the sealing performance of the lead door to ensure that the radioactive radiation cannot enter other areas through the door crack.
2.Protective measures for lead doors: On the walls and ground around the lead doors, radiation protection treatment should be carried out to avoid radiation leakage.
3.Identification of the lead door: There should be a clear sign on the lead door, indicating that it is the lead door of the radiation room, reminding people to pay attention to protective measures.
4.Maintenance of the lead door: Regularly check the status of the lead door to ensure that the door body is in good condition without any damage or wear, and repair and replace it if necessary.
The key points of the construction of the lead door in the DR room include the installation and precautions of the lead door. During construction, it is necessary to pay attention to ensure that the position of the lead door is reasonable, the size meets the requirements, and pay attention to the requirements of sealing, protective measures, identification and maintenance, so as to ensure the safety and radiation protection effect of the radiation room.