GB15811 test method of medical injection needle tip puncture force tester

Mondo Health Updated on 2024-02-17

In the medical field, the quality and safety of injection needles are of paramount importance. To ensure patient safety and the effectiveness of medical procedures, medical injection needles must undergo rigorous testing. Among them, the puncture force test is an important part of evaluating the performance of the injection needle, and the GB15811 medical needle tip puncture tester is mainly used for the physical performance testing of medical needles. This article will focus on the test methods and standard requirements of the GB15811 Medical Injection Needle Tip Puncture Tester to help you better understand the importance of this critical test.

1. Test method of GB15811 medical injection needle tip puncture tester.

The test method of GB15811 medical injection needle tip puncture tester is mainly divided into two parts: needle puncture force and pull-out force test:

1.Needle Puncture Force Test: This test measures the force required for an injection needle to puncture**. In the test, the injection needle is mounted on the testing instrument to pierce the simulated material at a calibrated speed. Record the peak force required for injection needle puncture simulation**.

2.Pull-out force test: This test measures the force required to pull the needle out of the simulation**. In the test, the injection needle is inserted into the simulation** at a certain speed and then withdrawn at a calibrated speed. Record the peak force required for the needle to be withdrawn from the simulation**.

2. Standard requirements of GB15811 medical injection needle tip puncture tester.

The standard requirements for GB15811 medical injection needle tip puncture tester include the following aspects:

1.Test speed: In order to simulate the speed in the actual injection process, the test speed should be within a certain range according to the standard requirements to ensure the accuracy of the test results.

2.Simulated Materials: The simulated materials used for testing should have physical and chemical properties similar to the real ones to bring the test results closer to the actual situation. The selection of simulated materials should comply with the relevant standards.

3.Peak force range: According to the standard requirements, the puncture force and extraction force of the injection needle should be within the standard range. This range should be adjusted according to different types of injection needles and different application scenarios to ensure that the injection needle has sufficient puncture and extraction force during use.

4.Test environment: The puncture force test of medical injection needles should be carried out under constant environmental conditions to ensure the accuracy of the test results. Environmental factors such as temperature, humidity, etc. should comply with the relevant standards.

5.Test equipment: The test equipment used for GB15811 medical injection needle tip puncture tester should meet the requirements of relevant standards to ensure the accuracy and reliability of the equipment. The equipment should be calibrated and maintained regularly to ensure the accuracy and consistency of test results.

In conclusion, the GB15811 medical injection needle tip puncture tester is a key link to ensure the quality and safety of injection needles. Understanding the test methods and standard requirements helps us to better evaluate the performance of needles and provide safer and more reliable medical care to patients, with enhanced testing and regulation to ensure the health and safety of patients.