Daze 15kw diesel generator oil circuit air treatment sometimes occurs in the oil circuit during use, which will lead to poor oil supply to the engine, or even unable to start. Therefore, the air treatment of the oil circuit of Daze diesel generator is particularly important. This article will introduce in detail the methods and precautions for oil air treatment of Daze 15kw diesel generator.
1. Daze 15kw diesel generator oil circuit air treatment method.
1.Check the fuel tank.
First of all, Daze 15kw diesel generator oil circuit air treatment should check whether the fuel tank is filled with diesel and make sure the fuel tank cover is well sealed. During transportation and storage, air may enter the tank due to reasons such as the tank cap is not tightly closed or the sealing gasket is damaged. Therefore, the tank and its seal should be checked before use.
2.Inspect the oil pipelines.
Check the oil pipeline for damage, looseness or oil leakage at the joints. If a problem is found in the oil pipeline, the damaged pipeline or loosely fastened joint should be replaced in time. At the same time, it is necessary to ensure the cleanliness of the oil pipeline and prevent debris from entering the oil pipeline.
3.Drain the oil air.
Before removing the oil air, the oil air treatment of Daze 15kw diesel generator should first turn off the fuel switch at the outlet of the fuel injection pump, then open the fuel tank release valve, and then slowly loosen the air release screw on the high-pressure oil pump. In the process of deflation, attention should be paid to observe the outflow of fuel, when the air entrained in the fuel is less, you can close the deflation screw, and tighten the fuel switch, and then open the fuel injection pump deflation valve to continue to deflate. Repeat the above steps several times until no air bubbles appear in the fuel. Finally, close the gas release valve of the fuel injection pump and slowly tighten the air release screw on the high-pressure oil pump.
2. Precautions for oil and air treatment of Daze 15kw diesel generator.
1.When removing the oil air, attention should be paid to safety. During operation, keep away from open flames and ensure that the workplace is well ventilated. At the same time, pay attention to the surrounding environment and avoid operating in a flammable and explosive environment.
2.During operation, special tools and equipment are used to operate. Do not use unsuitable tools or equipment to avoid damaging the equipment or causing accidents.
3.Before dealing with the oil channel air, you should first understand the structure and working principle of Daze 15kw diesel generator. For those who are not familiar with Osawa diesel generators, it is recommended to operate them under the guidance of professionals. At the same time, follow the operating instructions provided by the manufacturer and do not disassemble or change the parts of the device at will.
4.After the oil circuit air is treated, a test inspection should be carried out first. If the engine still does not work properly, it may be caused by other faults and should be inspected and repaired in time. At the same time, it is necessary to regularly inspect and maintain the Daze diesel generator to ensure the normal operation and service life of the equipment.