Method for troubleshooting Meineng UF 1015E hollow fiber ultrafiltration membrane

Mondo Military Updated on 2024-01-26

Meineng UF-1015E ultrafiltration membrane is an ultrafiltration membrane product with specific specifications and performance, which has a wide range of applications in water treatment, environmental engineering, medicine and health, industrial production and other fields. Especially in large-scale water treatment projects, the membrane can be used as an important technical means to achieve water purification and separation, and has broad market prospects and application potential. Below, the blue film water treatment will introduce to you its troubleshooting methods.

The following are some common troubleshoots and troubleshooting methods:

1.Decrease in water production:

a.Check whether the inlet water temperature is normal, if the temperature is too low, consider increasing the inlet water temperature.

b.Check if the inlet pressure is within the normal range, if the pressure is insufficient, consider increasing the head of the pump or replacing the pump.

c.Check the Meineng UF-1015E ultrafiltration membrane for blockage, such as blockage, chemical cleaning or mechanical cleaning.

d.Check if the performance of the membrane itself has deteriorated, and if so, consider replacing it with a new membrane.

2.Membrane leakage:

a.Check the membrane shell for damage, and if so, replace the membrane shell.

b.Check whether the membrane pad is aging, if it is aging, replace it with a new one.

c.Check that the membrane is installed firmly, and if not, reinstall it.

3.Membrane cleaning difficult:

a.Check that the cleaning agent is suitable, and if not, replace it with the appropriate one.

b.Check whether the cleaning frequency is appropriate, and if not, adjust the cleaning frequency.

c.Check whether the cleaning method is correct, and if not, follow the correct cleaning method.

4.Abnormal system pressure:

a.Check whether the inlet pressure is stable, if not, adjust the inlet pressure.

b.Check the system for leaks, such as leaks, find leaks and fix them.

c.Check the operating status of the pump, such as pump failure, replacement or repair of the pump.

5.The system is running too noisy:

a.Check the operating status of the pump, such as pump failure, replacement or repair of the pump.

b.Check the system for abnormal vibrations, such as excessive vibration, find the cause and fix it.

c.Check that the membrane is installed correctly, and if not, reinstall the membrane.

6.The operating temperature of the system is too high

a.Check if the inlet water temperature is too high, if so, take measures to reduce the inlet water temperature.

b.Check whether the membrane is over-cleaned, such as over-washing, and adjust the cleaning frequency and cleaning agent.

c.Check the system for blockages, if so, clean them.

In short, for the failure of Meineng UF-1015E ultrafiltration membrane, we need to discover, troubleshoot and solve it in time to ensure the normal operation of the system. At the same time, strengthen the maintenance and maintenance of the equipment, and improve the operation efficiency and service life of the equipment.

This article is original by Shenzhen Blue Film Water Treatment, giving people roses, hands have a fragrance, welcome to pay attention, take you to learn more about water treatment equipment information!