Efficient and accurate transformer winding deformation tester calibration device to improve test accuracy

With the continuous development of the power system and the aging of equipment, the problem of winding deformation of transformers during operation has attracted more and more attention. As an important test equipment, the transformer winding deformation tester is used to detect the winding status of the transformer, which is of great significance for ensuring the safe operation of the power system. However, since the accuracy of the test instrument directly affects the test results, how to improve the calibration accuracy of the test instrument has become an urgent problem to be solved. This article will introduce an efficient and accurate transformer winding deformation tester calibration device to improve the test accuracy.

1. The principle and significance of transformer winding deformation tester.

The transformer winding deformation tester mainly uses the electrical signal analysis method to judge the deformation of the transformer winding by detecting the changes in the electrical parameters of the transformer winding. The accuracy of the test instrument directly affects the accuracy of the test results, which in turn affects the judgment of the transformer status. Therefore, it is of great significance to improve the calibration accuracy of test instruments to ensure the safe operation of the power system.

2. The composition and principle of the calibration device of the efficient and accurate transformer winding deformation tester.

1.Signal Generator: Used to generate a signal similar to the electrical signal that may be encountered by the transformer in actual operation, for calibration by the test instrument.

2.Reference Standard Resistance: Used to determine the accuracy of the test instrument by comparing it with the electrical parameters measured by the test instrument.

3.Error analysis system: It is used to analyze the difference between the electrical parameters measured by the test instrument and the resistance of the reference standard, so as to obtain the error of the test instrument.

The principle of this calibration device is based on the electrical signal analysis method, which generates electrical signals that may be encountered in actual operation for calibration by the test instrument. Through the comparison with the reference standard resistance and error analysis, the accuracy of the test instrument can be determined, and the test accuracy can be improved.

3. Precautions for using an efficient and accurate transformer winding deformation tester calibration device.

1.Ensure that the signal generated by the signal generator is similar to the actual electrical signal to avoid calibration errors caused by signal differences.

2.The reference standard resistor should be checked and replaced regularly to ensure that its accuracy meets the requirements.

3.During the calibration process, the environment should be stable and quiet to avoid the influence of interference factors on the calibration results.

4.After the calibration is completed, the test instrument should be maintained and maintained to ensure its stable performance.

IV. Conclusions. In summary, an efficient and accurate calibration device for transformer winding deformation tester is of great significance to improve the test accuracy. The device consists of a signal generator, a reference standard resistor, and an error analysis system that can accurately calibrate the test instrument and improve the test accuracy. In practice, attention should be paid to signal differences, standard resistance accuracy, environmental interference, and instrument maintenance to ensure the effectiveness of the calibration device. With the continuous development of the power system, the application of transformer winding deformation tester will become more and more extensive, so it will be of far-reaching significance to improve the calibration accuracy of the test instrument.