Application of air tightness testing in the quality control of wall breakers

Mondo Cars Updated on 2024-01-31

Overview of detection.

In the electronics and mechanical engineering industry, it is essential to ensure the quality and durability of products. Especially for household appliances such as wall breakers, their air tightness is not only related to the performance of the product, but also directly affects the safety of users. For this reason, the use of high-precision air tightness testing is a key step. The purpose of this article is to introduce in detail the process of using HC classic series air tightness tester to test the air tightness of the wall breaker.

Product to be tested: wall breaker.

As a common kitchen appliance, the sealing performance of the wall breaker directly affects its safety and efficiency. Poor seals can lead to fluid leakage and even motor damage. Therefore, strict air tightness testing of the wall breaker is an important step to ensure its quality.

Inspection process. 1.Pressure setting: The detection pressure is set to 12kpa, which is the standard pressure to ensure the accuracy and safety of the test.

2.Leakage standard: The leakage value shall not exceed 003kpa。This standard ensures the sealing performance of the wall breaker under normal use conditions.

3.Test process:

Air intake: The test begins, and the air intake time is set to 10 seconds to fully inflate.

Voltage regulation: Voltage regulation for 10 seconds to ensure the consistency of test conditions.

Test: Perform an actual air tightness test for 5 seconds.

Deflat: After the test, deflate for 2 seconds to release the internal pressure.

The total test time is 27 seconds.

Inspection efficiency: According to this process, approximately 133 wall breakers can be inspected per hour.

In this test, HC Classic Series Air Tightness Tester is used. This instrument is widely used in the air tightness testing of various products because of its high accuracy, easy operation and good stability. It is equipped with customized fixtures that can be adapted to different models of wall breakers to ensure the accuracy and efficiency of inspection.

Instrument used: HC classic series air tightness tester.

Summary. Through the above-mentioned strict testing process and high-performance testing instruments, it can effectively ensure that the air tightness of each wall breaker meets the standard, and ensure the quality of products and the safety of users. This efficient inspection process not only improves production efficiency, but also earns the trust of consumers for the brand.

Related Pages