1. Construction goals and needs.
The main goal of data center room construction is to meet the needs of data processing and storage, while ensuring data security and system stability. During the planning phase, the following requirements need to be clarified:
1.The scale and needs of data storage and processing.
2.Data security and backup needs.
3.Availability and scalability of data centers.
4.Energy efficiency and sustainability in data centers.
2. Site selection and planning.
1. The following factors should be considered in the location of the data center computer room: geological conditions, surrounding environment, traffic conditions, electric power, etc.
2. The site plan should include the general layout of the data center, building structure, electric power, air conditioning system, network communication, etc.
3. Structural design.
1. The structural design of the data center room should consider the stability, load-bearing capacity, fire performance and other factors of the building structure.
2. In the structural design, the rationality and expansion of the equipment layout, as well as the convenience of personnel access and equipment maintenance should be considered.
4. Electricity & Energy**.
1. The electrical system of the data center computer room should include power supply, power distribution system, UPS system, etc., to ensure the stable power supply of the data center.
2. In terms of energy, the energy efficiency of the data center should be considered, and reasonable power supply methods and energy-saving measures should be adopted.
5. Network and communication systems.
1. The network system of the data center room should include local area network, Internet access, data transmission network, etc., to meet the needs of data processing and data exchange.
2. The communication system should include a network, a conference system, etc., to meet the needs of remote management and communication.
6. Security and Monitoring.
1. The security system of the data center computer room should include an access control system, a monitoring system, a fire protection system, etc., to ensure data security and personnel safety.
2. The monitoring system should include the monitoring of electric power, air conditioning system, network communication, etc., to ensure the stable operation of the data center.
7. Refrigeration and air-conditioning system.
1. The refrigeration system of the data center room should consider the reasonable distribution of hot and cold airflow to avoid hot spots and cold spots affecting the normal operation of the equipment.
2. The air-conditioning system should have an automatic adjustment function to meet the heat dissipation needs of the equipment under different loads and ensure the stable operation of the equipment.
8. Decoration and equipment arrangement.
1. The decoration of the data center room should be made of fireproof, moisture-proof, dust-proof and other materials to ensure the cleanliness and safety of the computer room.
2. The layout of facilities should consider the rationality and expansion of equipment layout, as well as the convenience of personnel access and equipment maintenance.
9. Construction and installation.
1. The construction and installation of the data center computer room should follow the relevant standards and specifications to ensure the construction quality and safety.
2. In the installation process, the convenience of equipment maintenance and expansion, as well as the safety of personnel access, should be considered.
10. Testing and acceptance.
1. In the test stage, all systems should be comprehensively tested to ensure the stable operation of the data center and data security.
2. In the acceptance stage, the acceptance should be carried out in accordance with the relevant standards and specifications to ensure the quality and safety of the construction.
Ten. 1. Maintenance and management.
1.The data center computer room has established a complete maintenance and management system, including daily inspection, equipment maintenance, fault handling, etc.
2.Systems should be inspected and maintained regularly to ensure the stability and security of the data center.
3.Data should be backed up and restored regularly to avoid data loss and corruption.
4.An emergency response plan should be established to ensure data security and integrity in response to unforeseen circumstances such as emergencies and natural disasters.