How to maintain an electronic belt scale in summer

Mondo Technology Updated on 2024-01-30

How to maintain the electronic belt scale in summer, do you know?Let's take a look!

How to maintain an electronic belt scale in summer

1. After a period of use, it is necessary to verify the accuracy of the belt scale, including: zero calibration and chain code calibration to detect its accuracy;

2. Check whether the electronic belt scale runs smoothly and without vibration, and whether the mechanical parts run flexibly and without gaps

3. If the electronic belt scale is installed indoors, it needs to be ventilated and dried in the high temperature and rainy season in summer to avoid overheating of the belt and affect the weighing accuracyIf it is installed outdoors, the various sensors and electronic equipment on the weighing frame need to be protected from rain, lightning and high temperatures

4. Check whether the belt operation is derailed;

5. Clean the belt scale regularly to remove unnecessary interference factors that affect its measurement accuracy.

6. There are many thunderstorms in summer, so it is necessary to ensure that the scale body is well grounded, otherwise the belt scale will be damaged by lightning

7. Do not weigh in thunderstorms, and disconnect all power supplies of the belt scale to prevent static electricity from lightning from interfering with electronic equipment.

8. In order to avoid problems in advance, it is necessary to produce safely in summer, and there can be no luck.

Parameter setting and calibration of weighing feeders.

1. Calibration of instrument parameters

After the belt tends to be stable for a period of time, the MT3105 instrument parameters can be set, such as the decimal point position of the input instrument, the unit of the scale, the capacity, the sensor capacity and sensitivity, the length of the belt and other parameters. The original parameters need to be entered for the first use, and there is generally no need to change them at will in normal use.

2. Calibration of weighing feeder:

First obtain the test cycle, and then carry out the zero point calibration, the zero point can be stabilized after the interval calibration, the interval calibration is divided into physical calibration, chain code calibration, hanging code calibration and other methods, the use of Ramsey special auto MAT (automatic material calibration) software, can automatically correct the interval value of the belt scale, after n times of calibration, so that the weighing to the weighing measurement standard, can be put into normal weighing measurement, cumulative.