Control equipment 4 20mA current data logger for power distributors, etc

Mondo Cars Updated on 2024-02-02

Multi-channel recorders can control 4-20mA output currents for devices, power distributors, etc.

Essentials. A current signal of 4-20mA can be converted to a voltage signal of 1-5V and recorded for a long time. Measurements can be made without the use of a dedicated current input unit.

How to use: 1.Prepare a resistor of 250 (1 4W or more). (Please prepare the resistor by yourself.) High-precision metal resistors are recommended).

2.Connect the resistor of 250 to the terminal block of the data logger (+ - between terminals) as shown in the figure.

3.With the BT3562A, the maximum inter-terminal voltage of DC100V can be measured. (BT3563A can measure up to DC300V).

4.1-5vF. of the data logger can be useds.Range.

For loop testing of two-wire transmitters, use the DC source SS7012.

Use the instrument. Data Logger LR8431-30 (10CH).

Data Logger LR8400-21 (with voltage temperature unit 2,30CH).

Data logger LR8401-21 (with universal unit 2, 30CH).

Data Logger LR8402-21 (with Universal Unit 1, Voltage Temperature Unit 1, 30CH).

DC signal source SS7012

(Please prepare the resistor by yourself.)

The information listed is based on the model number of the instrument issued in February 2022. Product specifications are subject to change, please refer to the current release.