Siemens 840D CNC operation appeared 597 code drive out of sync maintenance

Mondo Technology Updated on 2024-02-01

How much does it cost to repair Siemens CNC system: Siemens 840D CNC system is a fully digital CNC system with a highly modular and standardized structure. 597 profibus: drive out of sync Supplemental information: %x (data type: 16 base type) Shanghai Yangon Electronic Technology *** specializes in various brands of servo drive repair, servo motor repair, touch screen repair, inverter repair, servo maintenance, servo controller repair, CNC system repair and transformation, robot maintenance and various boards, chip-level maintenance and maintenance, free testing, fast repair, some immediate and so on!

Taicang Siemens CNC system maintenance is not limited to models:

Reason Additional Information:

0x01: The primary valid identifier (STW2, bits 12--15) has a continuous over-allowable failure. Valid for use.

The error of the identifier is specified using the parameter p0879 bit 2-0 (composed of profibus).

0x02: Global control messages are synchronized for clock cycles in operation in succession at several consecutive dp hours.

The clock cycle fails or violates the time specified by the parameterized message in several consecutive DP clock cycles.

Compartment (please refer to multiples of tdp and tpllw). If the entire dp loop communication fails continuously, again.

One more point, after the monitoring time of the most recent monitor specified at the time of bus composition has passed.

Barrier 599 will be output.

Action - Check if the communication has been interrupted briefly or continuously.

Check that the PROFIBUS main bus module can be operated in the clock cycle synchronization and that the clock cycle is the same.

Whether the global control packets required for the operation can be output in an equidistant dp clock cycle.

Check that clock cycle synchronization is activated in the bus composition, although it is not subject to the master bus mode used.

block-controlled. - Check if the main valid identifier (STW2, bits 12 15) is received and if it is being parameterized.

Clock loops have been added.

Resolve power on

Stop Response StopII