As a veteran steel mill power distribution room manager, I know the importance of temperature to the steel plant power distribution room. The power distribution room is one of the core facilities of the steel plant, which is responsible for the power ** and distribution, and ensures the normal operation of the entire production process. Temperature is one of the important factors that affect the performance, lifespan and safety of equipment and electrical components in the distribution room.
First of all, temperature has a direct impact on the performance and longevity of equipment in the distribution room. In a high-temperature environment, electrical equipment is prone to overheating, resulting in the deterioration of the insulation performance of electrical components, and even causing equipment failure and fire. In a low temperature environment, the mechanical properties of electrical equipment will be affected, resulting in unstable operation of the equipment. Therefore, maintaining the right temperature is essential to extend the service life and reliability of the equipment.
Secondly, the temperature has an important impact on the safety of the distribution room. In a high-temperature environment, electrical equipment is prone to sparks, which can lead to fires. In the low temperature environment, the mechanical properties of electrical equipment are reduced, which is easy to cause equipment failure, thereby affecting the safe operation of the power distribution room. Therefore, maintaining the right temperature can effectively reduce the risk of fire and equipment failure, and improve the safety of the distribution room.
Explosion-proof air conditioning is an effective solution to the temperature problem in the distribution room of a steel plant. Explosion-proof air conditioning is an air-conditioning equipment specially designed for hazardous environments, which has the characteristics of explosion-proof, anti-corrosion, dust-proof, etc. It can keep the temperature of the distribution room within a safe range in a high-temperature environment to avoid overheating of equipment and the occurrence of fire. At the same time, explosion-proof air conditioning can also filter dust and harmful gases in the air, ensure the air quality of the power distribution room, and improve the comfort of the working environment.
When configuring explosion-proof air conditioners, the specific conditions and needs of the distribution room need to be considered. First, determine the appropriate capacity and number of air conditioners according to the size and layout of the distribution room. Secondly, choose an explosion-proof air conditioner that meets explosion-proof standards to ensure its safe performance in hazardous environments. At the same time, it is also necessary to consider the energy consumption and maintenance cost of the air conditioner, and choose a cost-effective product.
In short, as a steel mill distribution room manager, I know the importance of temperature to the distribution room. Reasonable temperature control can improve the performance and life of equipment, reduce the risk of fire and equipment failure, and ensure the safe operation of the power distribution room. Configuring explosion-proof air conditioning is an effective means to solve the temperature problem of the distribution room of the steelmaking plant, and it is necessary to choose the right product according to the actual situation, and pay attention to the control of energy consumption and maintenance costs.
Explosion-proof wall-mounted air conditioner.
BHKT-25-EX Cooling capacity: 2500W Heating capacity: 2550W Voltage: 220V 50Hz Reference applicable area: 10-12
BHKT-35-EX Cooling Capacity: 3500W Heating Capacity: 4200W Voltage: 220V 50Hz Reference applicable area: 12-16
BHKT-50-EX Cooling capacity: 5000W Heating capacity: 6200W Voltage: 220V 50Hz Reference applicable area: 20-26
BHKT-75-EX Cooling capacity: 7500W Heating capacity: 9300W Voltage: 220V 50Hz Reference applicable area: 30-40
Explosion-proof vertical cabinet air conditioner.
BHKG-50-EX Cooling capacity: 5000W Heating capacity: 6200W Voltage: 220V 50Hz Reference applicable area: 20-26
BHKG-75-EX(F) Cooling capacity: 7500W Heating capacity: 9300W Voltage: 220V 50Hz Reference applicable area: 30-40
BHKG-75-EX Cooling capacity: 7500W Heating capacity: 9300W Voltage: 380V 50Hz Reference applicable area: 30-40
BHKG-120-EX Cooling capacity: 12000W Heating capacity: 15500W Voltage: 380V 50Hz Reference applicable area: 50-60
BHKG-160-EX Cooling capacity: 16000W Heating capacity: 19500W Voltage: 380V 50Hz Reference applicable area: 75-85
BHKG-250-EX Cooling capacity: 25000W Heating capacity: 28000W Voltage: 380V 50Hz Reference applicable area: 100-120
Explosion-proof ducted air conditioner.
BHKT-25-EX(F) Cooling capacity: 2500W Heating capacity: 2550W Voltage: 220V 50Hz Reference applicable area: 10-12
BHKT-35-EX(F) Cooling capacity: 3500W Heating capacity: 4200W Voltage: 220V 50Hz Reference applicable area: 12-16
BHKT-45-EX(F) Cooling capacity: 4000W Heating capacity: 4500W Voltage: 220V 50Hz Reference applicable area: 18-22
BHKT-50-EX(F) Cooling capacity: 5000W Heating capacity: 6200W Voltage: 220V 50Hz Reference applicable area: 20-26
BHKT-65-EX(F) Cooling capacity: 6500W Heating capacity: 7400W Voltage: 220V 50Hz Reference applicable area: 25-30
BHKT-75-EX(F) Cooling capacity: 7500W Heating capacity: 9300W Voltage: 220V 50Hz Reference applicable area: 30-40
BHKT-120-EX(F) Cooling capacity: 12000W Heating capacity: 15500W Voltage: 380V 50Hz Reference applicable area: 50-60
BHKT-140-EX(F) Cooling capacity: 14000W Heating capacity: 15500W Voltage: 380V 50Hz Reference applicable area: 60-70
BHKT-250-EX(F) Cooling capacity: 25000W Heating capacity: 28000W Voltage: 380V 50Hz Reference applicable area: 100-120
BHKT-280-EX(F) Cooling capacity: 28000W Heating capacity: 39500W Voltage: 380V 50Hz Reference applicable area: 120-140
BHKT-300-EX(F) Cooling capacity: 30000W Heating capacity: 39500W Voltage: 380V 50Hz Reference applicable area: 120-140
BHKT-500-EX(F) Cooling capacity: 50000W Heating capacity: 56000W Voltage: 380V 50Hz Reference applicable area: 220-240
Explosion-proof patio air conditioning.
BHKT-50-EX(T) Cooling capacity: 5000W Heating capacity: 6200W Voltage: 220V 50Hz Reference applicable area: 20-26
BHKT-75-EX(T) Cooling capacity: 7500W Heating capacity: 9300W Voltage: 220V 50Hz Reference applicable area: 30-40
BHKT-120-EX(T) Cooling capacity: 12000W Heating capacity: 15500W Voltage: 380V 50Hz Reference applicable area: 50-60
The selection of dehumidification capacity and model of dehumidifier is mainly calculated scientifically according to the volume of the use of environmental space, the size of fresh air volume, and the humidity requirements required by the space environment. In addition, it should be noted that the relative humidity of the environment is related to the temperature of the environment, the higher the temperature, the faster the humidity evaporates, and the worse the effect, so when configuring the dehumidifier, you need to select the type under the guidance of professionals, so as to choose the most suitable dehumidifier for you!
The formula for calculating the dehumidification capacity is w=v*p*(x2-x1) 1000*12 (kg h) [w = required dehumidification capacity (kg h), p = air density (kg m3) 12. v = site volume, x2 = air humidity content before dehumidification, x1 = air humidity content after dehumidification, 12=Safety Factor (Loss)].