XJL-1200A gas cylinder valve drop weight impact testing machine, our company developed the relevant evaluation test method for the impact resistance of gas cylinder valves, which is a test instrument used to evaluate the impact resistance of valve body components. At the same time, the impact comparison test can also be carried out on the samples of the same material and the same specification to identify the quality of the material. It is applicable to both the through-pass method and the gradient method.
This testing machine adopts program control technology, which can preset the impact height, automatically lift the hammer to a predetermined height, and display the height at any time. The number of impacts can be set to achieve continuous impact, the machine has good reliability and high precision, and meets the requirements of the professional standard ZBN72026 drop weight impact testing machine technical condition standard.
Main technical parameters:
1. Maximum impact energy: 1200J
2. Minimum impact energy: 210J
3. Operating temperature: 10-35
4. There is no large vibration source nearby, and there is no strong electromagnetic field.
5. There is no corrosive medium in the environment, and attention should be paid to the good ventilation of the electric control box.
6. Power supply: AC 220V 10% 2A
7. Total weight of hammer body: 65kg
8. Counterweight: 5kg six.
9. Basic hammer weight: 35kg
10. Hammer mass accuracy: 05%
11. Worktable: 600 600mm (can be customized according to user requirements).
12. Workbench installation form: trapezoidal groove M20
13. Hammer head form: the cylindrical head is spherical, 13mm
14. Maximum impact height range: 2000mm
How it works:
There is an automatic hanging hammer beam in the guide pillar of the testing machine, the hanging hammer fixture on the beam is connected with the chain, through the operation of the motor and the reducer, the beam is driven to lift the hammer body, and the hammer body automatically stops when it rises to the required height, presses the drop hammer switch, the electromagnet acts, and the opening and closing fixture is opened, so that the hammer body falls freely in the guide pillar and impacts on the sample, so as to achieve the purpose of the test.