As a commonly used sanitation equipment, the fecal suction truck needs to be operated in a standardized manner in daily use to avoid improper damage and failure. Below we summarize the common faults and solutions of fecal suction trucks, hoping to help you better understand and deal with the problems of fecal suction trucks.
First, the solution to the leakage of the hole cover of the fecal suction truck.
1.Tie rod is too long: Adjust the length of the tie rod to make it suitable for hole cover sealing;
2.Left-hand screw not screwed in place: Screw the left-hand screw into place to ensure a seal;
3.Gasket damage failure: Replace the gasket in time to ensure sealing performance.
Second, the solution of the vacuum gauge reading of the fecal suction truck is too low or there is no indication value.
1.The speed of the vacuum pump is too low: increase the throttle to increase the speed of the vacuum pump
2.Damaged vacuum gauge: Replace the vacuum gauge to ensure accurate readings
3.Vacuum gauge tube blockage: remove the blockage and restore the smooth flow of the pipe;
4.The four-way ball valve is not opened in place: replace the rotary vane to ensure the normal operation of the four-way ball valve.
3. The solution to the abnormal noise or high temperature rise of the vacuum pump.
1.Wheel liner wear: Replace the wheel liner in time to keep the vacuum pump running normally
2.Impurities or debris entering the pump room: dismantle, inspect and clean the vacuum pump, replace worn parts, ensure that the pump room is clean;
3.Insufficient lubricating oil and mixed with impurities: add or replace lubricating oil in time to ensure the normal operation of the lubrication system.
Fourth, the solution to the oil leakage of the fuel tank of the fecal suction truck.
1.Gasket damage: Replace the gasket to ensure the sealing performance of the tank;
2.Loose connecting screws: tighten the bolts to eliminate the hidden danger of oil leakage;
3.Too much lubricating oil: Make sure the lubricant is in the proper place to avoid the oil spillage.
5. The solution to the abnormal sound of the power take-off or the temperature rises.
1.Wear and tear of parts: disassembly and inspection, cleaning of power take-offs, timely replacement of worn parts;
2.Lubricating oil has impurities or insufficient quantity: keep the lubricating oil clean, replace or add lubricating oil in time.
In the process of daily use of fecal suction trucks, the above problems may occur, and timely discovery and correct solutions can effectively avoid equipment damage, prolong the life of equipment, and improve work efficiency. I hope that the fault solutions described in this article can help you who use fecal suction trucks and make the use of sanitation equipment smoother and more efficient.