1. When the water temperature decreases and the water yield of the reverse osmosis equipment decreases, attention should be paid to the warmth of the reverse osmosis equipment. At the same pressure, the temperature drops by one degree Celsius, the water yield can be reduced by 3-4%, and the inlet water temperature for reverse osmosis is 25 degrees Celsius.
2. Add insulation materials to the raw water tank (inlet pipeline) and water pump of the water treatment systemPrevent pipelines, water pumps, etc. from freezing due to low temperature, which will affect the operation of equipment.
3. Empty the raw water tank, raw water pump, multi-media filter, activated carbon filter, antiscalant dosing system, precision filter (security filter), high-pressure pump, reverse osmosis system, ultrafiltration system, ultrapure water system, pure water tank and connected pipelines that are not used temporarily, and then add medium to run when using to prevent the system from icing and damage to the internal medium due to non-operation
4. The parameters of the water treatment system in operation should be checked in time to ensure that the parameters are within the normal range, if the operating parameters are too high or too low, please contact the company's business personnel or technical personnel in time to avoid unnecessary damage!
5. The water treatment system in operation must ensure that the indoor heating can be ensured, the indoor temperature must be increased, and the raw water inlet temperature must be increased, and the temperature must be at least 18 and the best temperature is 20-25;Please be sure to take good precautions to avoid unnecessary damage!