What fire extinguishing measures should be taken to deal with the fire in the energy storage station

Mondo Social Updated on 2024-01-31

As an important facility for energy storage, once a fire occurs, the consequences of energy storage stations are unimaginable. Therefore, it is crucial to take the right fire extinguishing measures. In view of the fire of the energy storage station, perfluorohexanone should be used to extinguish the fire first, and on this basis, whether to start the water sprinkler system should be considered according to the fire situation. belowFudge TechnologyThese two extinguishing measures will be described in detail.

To inquire about energy storage fire protection, please click below to contact:

Electrochemical energy storage fire protection system solution provider - Fuji Technology.

1. Perfluorohexanone fire extinguishing measures

Perfluorohexanone is a new type of environmentally friendly fire extinguishing agent, which has excellent fire extinguishing performance and environmental protection characteristics. When dealing with a fire at an energy storage station, perfluorohexanone should be used first to extinguish the fire. Here's how:

1.Arrive at the fire scene quickly: Once the alarm of a fire at the energy storage station is received, firefighters should quickly dispatch to the fire scene. After arriving at the scene, you should immediately understand the layout of the energy storage station, the fire situation and the personnel situation, so as to prepare for the follow-up fire extinguishing work.

2.Start the perfluorohexanone fire extinguishing system: The energy storage station should be equipped with a perfluorohexanone fire extinguishing system, and in the event of a fire, the system should be activated quickly. By spraying perfluorohexanone extinguishing agent, the fire is quickly extinguished and the spread of the fire is suppressed. Perfluorohexanone fire extinguishing agent has the advantages of non-conductivity and no residue, no damage to equipment, and can effectively ensure the safety of energy storage stations.

3.Safe evacuation of personnel: While activating the perfluorohexanone fire extinguishing system, the staff and firefighters of the energy storage station should quickly organize the safe evacuation of on-site personnel. Ensure that all personnel are safely evacuated from the fire scene and prevent the creation of personnel.

2. Water sprinkler fire extinguishing measures

If the fire is not effectively controlled after perfluorohexanone, a sprinkler system should be considered. However, it should be noted that sprinkler systems are not suitable for all types of energy storage station fires. Before initiating sprinkler extinguishing measures, the fire situation should be fully assessed to ensure that no further damage is caused to the energy storage equipment. If it is confirmed that a sprinkler can be used to extinguish the fire, here's how:

1.Turn on the water sprinkler system: Turn on the water sprinkler system to ensure that no further damage is caused to the energy storage device. By spraying a large amount of water, the temperature of the fire is reduced, so as to achieve the purpose of extinguishing the fire.

2.Prevent the risk of electric shock: Due to the conductive nature of water, special care should be taken to prevent the risk of electric shock when using water sprinklers to extinguish fires. Firefighters should wear insulated protective gear to ensure their own safety. At the same time, it should be kept away from the fire equipment as much as possible to avoid the risk of electric shock caused by damage to the equipment.

3.Cooperate with other fire extinguishing measures: When using water sprinkler to extinguish the fire, it should be combined with other fire extinguishing measures, such as the use of foam fire extinguishing agent. Through the joint application of a variety of fire extinguishing methods, the fire extinguishing effect is improved and the fire is extinguished as soon as possible.

4.Personnel safety and security: Special attention should be paid to ensuring the safety of on-site personnel when taking sprinkler fire extinguishing measures. Ensure that all personnel are away from the fire to prevent accidents such as injuries or electric shocks caused by water spray.

To sum up, in the case of a fire in the energy storage station, perfluorohexanone should be used to extinguish the fire first, and on this basis, whether to start the water sprinkler system should be considered according to the fire situation. When taking any fire extinguishing measures, the fire situation should be fully assessed to ensure the safety of personnel and equipment. At the same time, the energy storage station should be equipped with complete fire protection facilities and safety measures, and conduct fire drills and safety inspections regularly to deal with the occurrence of various emergencies.