What are the specific steps to clean and replace the cartridges?

Mondo Gastronomy Updated on 2024-02-27

The cleaning and replacement steps of the filter cartridge in a food factory may vary depending on the type and model of the cartridge, and the following are the general cleaning and replacement steps:

1.Close the feed valve of the cartridge filter.

and the discharge valve, and drain the material from the filter in parallel.

2.Remove the casing of the cartridge filter and remove the cartridge.

3.Put the filter cartridge into the cleaning tank, rinse the surface of the filter cartridge with clean water, and remove the residual material.

4.Using tools such as brushes or high-pressure water guns, clean the inside of the cartridge to remove residual material and microorganisms.

5.Use a disinfectant or sterile agent to disinfect or sterilize the cartridge.

6.Place the cleaned and sterilized cartridge in a well-ventilated area to dry.

7.Install the dried cartridge into the filter and make sure it is securely installed.

8.Open the feed and discharge valves of the filter and check whether the filter is operating properly.

Dust filter cartridge

It is important to note that when cleaning and replacing the filter cartridges, the relevant safety operating procedures need to be followed to ensure the safety and health of the operators. At the same time, cleaned and replaced cartridges need to be tested to ensure they meet food safety standards.