u sonic WS7Weather Sensor

Mondo Social Updated on 2024-03-06

u[Sonic]ws7weather sensor.

Apply. Meteorological applications.

Onshore and offshore wind turbines.

Construction & Environmental Technology.

Traffic and Industrial Meteorology.

Wind warning and event technology.

Large-scale photovoltaic power plants.

Alpine application.

Seven meteorological parameters in one device.

The wind direction and speed of the u[sonic]ws weather sensor are measured by the super S-wave sensor, which determines the air temperature, humidity and pressure values in addition to the wind parameters; Calculate the dew d. The flake cover of the humidity and temperature sensor protects the sensor from climatic deterioration and ensures improved and more accurate measurements. There are a variety of interfaces and protocols to choose from. u[Sonic]WS7 does not have an X system in terms of applications.

No moving measuring cell, no wear.

Seven weather parameters: wind direction and speed, air temperature, relative humidity, air pressure, global radiation, dew

Intelligent heating according to wind speed and direction.

Sheet cover for measuring temperature and humidity sensors.

Easy to install and easy to maintain.

Number: 0016480.001000

Measuring range wind direction: 0....359.9°

Measuring range wind speed: 0....65 m sec.

Measuring range air temperature: -40....70 degrees Celsius.

Measuring range relative humidity: 0....100 %

Measuring range air pressure: 300....1100 mbar.

Measuring range global radiation: 0....2000 w/m2 • 285...Global radiation in the range of 3000 nm.

Accuracy wind direction: < 2° (1 m s) rmse

Accuracy wind speed: 02 m/s rmse (v < 10 m/s) •2 % rmse (10 < v < 65 m/s)

Accuracy Air temperature: 01k (0...60 °c) •0.2k (-40...0 °C) >2 msec.

Accuracy Relative Humidity: Typical 15 % 0...80 %)2 % 80 %)

Accuracy air pressure: 05 mbar.

Resolution wind direction: 01°

Resolution wind speed: 01 msec.

Resolution air temperature: 01° Celsius.

Resolution is related to humidity: 01 %

Resolution air pressure: 01 mbar.

Resolution Global Radiation: 02 W2

Nonlinearity: < 1 % 100....1000 w/m2)

Trigger threshold: 01 msec.

Output: RS 485 · RS 422 (optional • Please specify when ordering: ID: 97.)16470.000422 Configure RS 422 output).

Protocol: NMEA 0183

Modbus RTU (optional 97.)16470.000001 Configure modbus).

SDI-12 (optional 97.)16470.000002 Configure SDI-12).

Other agreements are available upon request.

Interface: RS485 422 SDI-12 (optional).

Measurement rate: 01...10 Hz.

Operating conditions: -40....70 °C (heated: -50...)70) •0...100 % r. h.

Z strong wind speed: 100 m sec.

Power Voltage: Without Heating: 6....60 VDC with heating : 24 V AC DC 20 %

Current consumption: Sensor: 50 mA typical at 24 VDC Heating: 10 A max at 24 V AC DC

Measuring Elemental Global Radiation: Thermopiles with High-Quality Thermoelectric Cells.

Measuring principle of global radiation: thermoelectric.

Heating data: factory configurable: 60 W; 120 watts; 200w (default).

Dimensions: 199 mm and height 284 mm

Resistant to seawater aluminum. Degree of protection: IP 66 IP 67

Weight: about 34 kg

Fittings. 32.16470.060000 sensor cable, 15 m, 8-pole M16 plug.

Related Pages