Structural features of the HYDAC filter unit MFU 15E9 SM FE

Mondo Cars Updated on 2024-01-31

Structural characteristics of HYDAC filtration device MFU-15E9-SM-FE

HYDAC's MFU-15E9-SM-FE filtration unit is a highly efficient, portable filtration device designed to handle a wide range of fluids. The following is a detailed introduction to the MFU-15E9-SM-FE filter device:

First, the design principle.

The MFU-15E9-SM-FE filter unit uses advanced filtration technology to remove solid particles and free water from the fluid through the filter element. The design principle is based on the principle of high-efficiency filtration and low resistance, ensuring that a high level of filtration performance is maintained even when handling large volumes of fluids.

Second, the main features.

High-efficiency filtration: The filter device uses high-quality filter elements, which can effectively remove solid particles and free water in the fluid, and improve the cleanliness of the fluid.

Portable Design: The MFU-15E9-SM-FE filter unit has a compact design that is easy to carry and move, making it easy to use in a variety of environments.

Long-life filters: The unit uses long-life filters, which reduces the frequency of filter replacement and maintenance costs.

Easy to clean: The filter device has a simple structure, easy to disassemble and assemble, and is easy to clean and maintain.

High reliability: The unit is manufactured with high-quality materials and mature processes, which ensures its high reliability and stability.

Environmental protection: The filter device adopts environmentally friendly filter element, which reduces the pollution to the environment.

3. Scope of application.

The MFU-15E9-SM-FE filter device is widely used in various occasions that require clean fluids, such as:

Hydraulics: Used to fill hydraulics, flush small hydraulics, and clean bypass flows.

Pneumatic system: It is used to provide a clean gas source and prevent impurities and particles in the air from causing damage to pneumatic equipment.

Laboratory research: It is used for experiments and research on various fluids that require high cleanliness, such as chemical reactions, biological experiments, etc.

Industrial production: It is used in various industrial production processes that require clean fluids, such as machining, pharmaceuticals, etc.

Fourth, the operation steps.

Inspection before use: Before using the MFU-15E9-SM-FE filter unit, it should be checked for its appearance to be intact to ensure that there is no obvious damage or defect. At the same time, the integrity of the filter element should be checked, and if the filter element is found to be damaged or blocked, it should be replaced in time.

Installation: Install the filter unit on equipment that needs to be cleaned fluid, making sure the connection is secure and well sealed. Typically, the unit can be connected to the device via a quick coupling or hose.

Operation: Turn on the power or air supply of the unit, start the filtration unit, and start processing the fluid. Pay attention to the operating status of the equipment to ensure that the fluid passes through the filtration device and is effectively cleaned.

Cleaning and maintenance: Regular cleaning and replacement of filters is an important step in maintaining the performance of your filtration unit. Depending on the usage, the filter can be removed periodically for cleaning or replacement. At the same time, the integrity of the seals and other components of the equipment should be checked regularly, and replaced in time if necessary.

Precautions: During use, care should be taken to avoid severe vibration or impact of the filter device. At the same time, the use of the device in hot or humid environments should be avoided. In addition, the operating status of the equipment should be checked regularly to ensure its proper operation.

5. Care and maintenance.

In order to ensure the long-term stable operation and service life of the MFU-15E9-SM-FE filter unit, proper care and maintenance are crucial. In addition to routine cleaning and inspections, filters and other critical components should be replaced regularly. If any abnormal conditions or performance degradation are found during use, professionals should be contacted in time for maintenance and repair. In addition, it is advisable to establish detailed maintenance records in order to track the maintenance history of the equipment and potential problems.

Pressure Sensor Series:

hda 4445-4-016-000

hda 4445-a-060-000

hda 4445-a-100-000

hda 4445-a-250-000

hda 4445-a-400-000

hda 4445-a-600-000

hda 4445-b-016-000

hda 4445-b-040-000

hda 4445-b-060-000

hda 4445-b-100-000

MFU 15 mobile filter unit.

FCC Fluidcarrier Compact.

FCM FluidCleaner Mobile.

ft 5 drum transport and filter trolley.

of 5 Mobile filtration unit.

TW 5 Mobile Oil Transfer and Filtration Unit.