Troubleshoot the cause of the failure of HEIDENHAIN CNC system TNC310 not running.
1. The unstable switching power supply or the unstable voltage of the switching power supply or the abnormal power supply system will also lead to the normal operation of the numerical control. Solution: Check whether the power supply distribution line is good in touch, whether there is looseness, check whether the switching power supply application is compliance management, and whether the switching power supply has problems.
2. There is a problem with the certified mechanical parts.
Defects or damage to mechanical components such as transmission components and threads of HEIDENHAIN's education control system will have a significant impact on the operation of the equipment. Solution: Check the mechanical part in time to avoid damage to the mechanical part caused by negligence and improper operation, you can consider regular maintenance or maintenance, or choose high-quality machinery to strengthen the quality of the equipment.
3. There is an error in the control system program.
Errors in the control system program can lead to HEIDENHAIN CNC errors. Solution, review the accuracy and completeness of the control system, ensure that there is no problem with the program, adjust the program parameters of the control system, and ensure that the equipment can operate normally.
4. Cable connection problems.
The problem is that the cable is not plugged in or falls off, etc., and the solution is to clean the cable regularly, check whether the wire connection is stable and firm, and ensure that the connection has an impact on the cable when it is connected, so as to avoid the connection problem.
Heidenhain CNC system not running troubleshooting:
1.Check whether the power supply distribution line is good in touch, whether there is looseness, check whether the switching power supply application is compliance management, and whether there are any problems in the switching power supply.
2.Check whether the distribution line is good in touch, whether it is loose, and check whether there is a short circuit or short circuit.
3.Inspect mechanical parts: Check whether there are defects or damage to mechanical parts such as transmission parts and threads.
4.Check the sensor: Check if the sensor is working properly and for damage or malfunction.
5.Check the control system program: check whether the control system program has errors or failures, ensure that there is no problem with the program, and adjust the control system program parameters.
6.Check the wire connection: Check whether the wire connection is intact and whether the cable is loose or damaged.
7.Check the configuration of the HEIDENHAIN CNC system: Check whether the configuration of the HEIDENHAIN CNC system is correct, such as whether the system configuration is correct.