What are the requirements for the customization of mobile environmental protection toilets in scenic

Mondo Home Updated on 2024-02-20

In order to ensure the coordination of the landscape of tourist attractions, tourist attractions also have certain requirements for mobile toilets.

A ...AAA level tourist toilet construction requirements

1.General requirements Comply with the current national standards for the construction of public toilets, and places without water supply and water should adopt toilet technologies that meet environmental protection requirements, simple maintenance, economical and reliable (such as: water-saving, foam-free flushing, circulating flushing and bio-type, etc.);

2.Men's and women's toilets Men's and women's toilets should be set up separately;

3.The exterior of the building and the external environment should meet the following requirements:

a) The exterior style should reflect the regional culture and be in harmony with the surrounding environment and architecture;

b) The color palette should reflect the regional culture and blend in with the surrounding environment;

c) The entrance of the toilet is designed according to the characteristics of the local climate, and attention should be paid to privacy protection, open entrances can be used in tropical areas, and thermal insulation needs should be considered in cold areas, and transitional spaces should be set up. When the toilet is set up with a door, the door leaf and door frame should be anti-pinching. The material is sturdy and durable, in keeping with the architectural style of the toilet.

d) Decorative materials should be based on regional characteristics of local materials, as little as possible to use industrial materials, in order to reduce carbon emissions, the main building materials should be weatherproof, anti-corrosion, pollution-free environmental protection building materials, fire performance should meet the requirements of GB50016.

e) The surrounding environment of the tourist toilet is natural and harmonious.

The interior layout and decoration of the building shall meet the following requirements:

a) The construction area is more than 80 meters;

b) Separate toilet indoor clear height 3More than 2m (it can be appropriately lowered when setting a skylight), and the attached public toilet is according to the height of the building;

c) The indoor ceiling is made of moisture-proof, anti-corrosion and easy-to-clean materials; d) The walls of toilets and toilets should be made of waterproof, fireproof and easy-to-clean materials;

e) The toilet indoor floor should be waterproof before paving, and the decorative surface should be made of anti-slip, anti-seepage and anti-corrosion materials; The tone of the ground in the toilet should be uniform, the ground height should be consistent, and the requirements for environmental protection toilets can be relaxed according to the needs of the equipment;

f) All indoor water, electricity, HVAC and other pipelines should be concealed;

g) The management room is designed according to the management and service needs, and the usable area should be more than 6.

h) Indoor toilet buildings should be equipped with green plants, potted flowers or other decorations in public areas.

Water supply and drainage shall meet the following requirements:

a) The layout and installation of water supply and drainage pipelines of tourist toilets should meet the requirements of GB50242 "Code for Acceptance of Construction Quality of Building Water Supply and Drainage and Heating Engineering", and the northern region should meet the requirements of anti-freezing;

b) The water supply pipeline should be set up before entering the house, and the toilet should be equipped with an emptying valve, and the inner diameter of the pipe should not be less than 50;

c) After the drainage main road is out of the house, a well should be set up and anti-seepage treatment should be carried out; Exhaust pipes should be provided on the main road; The floor of the toilet should be equipped with anti-corrosion water seal floor drain, and the location and quantity should be set reasonably to ensure that there is no stagnant water on the ground; The diameter of the main drainage pipe of the toilet is more than 200, and the material is smooth, firm and anti-corrosion.

Two. Facilities for special populations:

1. Barrier-free facilities should comply with GB50763 "Barrier-free Design Code".

2. The toilet should be equipped with a third toilet, and should meet the following requirements:

a) The location should be close to the entrance of the public toilet to facilitate the entry of people with reduced mobility, and the wheelchair rotation radius should not be less than 15m;

b) Internal settings may include: toilets, children's toilets, children's urinals, wash basins, children's wash basins, multi-purpose tables, child safety seats, coat hooks and pagers;

c) The usable area should not be less than 65㎡;

d) The ground should be non-slip and not waterlogged;

E)** Toilets, wash basins, multi-function tables, safety grippers, coat hooks, and call buttons shall comply with the provisions of the current standard "Code for Barrier-free Design" GB50763;

f) The multi-function table and child safety seat should be foldable, the length of the child safety seat should not be less than 450, the width should not be less than 420, the height should be 500, and the ground clearance should be 300;

g) There should be a third toilet sign at the entrance.

3. The toilet should conform to the beliefs and customs of the local people

4. Proportion of toilets

a) The ratio of male to female toilets (including male urinals) is 2:3;

b) The ratio of squatting positions should be at least 1:4;

c) Men's toilets should be mainly urinal.

d) At least one toilet stall marked as accessible and with standard accessible handrails.

5. Toilet size and configuration

a) The net size of the squatting toilet should not be less than 14m, width 12m;

b) The toilet stall is secretly equipped with an unmanned indication device, and the door lock is firm and can be opened inside and outside;

c) The toilet partition should be made of solid, moisture-proof, anti-corrosion, anti-scalding, and easy-to-clean materials, and the metal partition should be used, and the height of the partition board (door) is 18m or more.

Three. Sanitary utensils

Squatting toilet. 1. Squatting toilets should be selected under the condition of water supply and discharge. Squatting toilets should meet the requirements of GB6952 "Sanitary Ceramics" and GB T18092 "Water-free Flushing Sanitary Toilets", and domestic brand toilets should be selected, which are durable, hygienic and water-saving, simple and generous.

2. Squatting toilet cleaning:

a) The water flushing type should be flushed by inductive water-saving flushing valve or non-touch mechanical valve;

b) The water-free flushing or circulating flushing type should be cleaned by induction or touchless mechanical cleaning to achieve the effect of hygienic cleaning.

3. The following auxiliary facilities should be set up in the squatting toilet seat, and the appearance should be coordinated with the overall interior

a) 2 cartons in each toilet stall;

b) Discarded toilet paper is placed, and there is a non-touch trash can with a lid in each toilet stall;

c) Handrails, at least one should be installed in each toilet stall, the installation is firm, the position is reasonable, and it is advisable to choose antibacterial function.

d) Coat hooks, each toilet is equipped with 2 coat hooks, and the load capacity is not less than 5kg.

Urinal

1. Urinal quality:

a) Brand porcelain semi-hung urinals should be used;

b) The distance between urinals should be 08m or more.

c) The station partition should be made of sturdy, moisture-proof, anti-corrosion, anti-scalding, and easy-to-clean materials, with a width of 05m, 08m or more.

2. Urinal cleaning:

a) The water flushing type should adopt inductive water-saving automatic flushing valve or non-touch mechanical valve;

b) The water-free flush type should be convenient to handle and easy to clean.

Hand hygiene equipment

1. The number of wash basins is set with reference to CJJ14-2005 "Design Standards for Urban Public Toilets".

The number of toilets is less than 4, and there is 1 toilet.

The number of toilets is 5--8, and there are 2 toilets.

The number of toilets is 9-21, with 1 additional toilet for every 4 toilets;

The number of toilets is more than 22, and 1 toilet is added for every 5 toilets.

Description:

Men's and women's toilets should be calculated separately and set up separately;

When the number of wash basins in the women's toilet is n5, the actual setting is n=08n calculations.

Hand cleaning equipment

a) There is a water type should be selected brand wash basin and faucet, the installation is firm, the faucet should be selected without touch, hot and cold water should be provided during the opening hours, and the faucet should be selected to meet the five-star quality certification trademark of the bathroom quality products; Hand sanitizer containers, at least one per wash basin;

b) Sensor-type hand cleaning equipment, disinfectant wipes, etc. should be provided for the waterless type to ensure effective hand hygiene.

Hand drying equipment

a) Men's and women's toilets should be equipped with 2 hand dryers, at least one sensor hand dryer and one integrated tissue box;

b) An integrated tissue box with a garbage can should be set up in the public area, which should be in-wall.

Mask

Through-chip or free-standing, with light or sensor lamp.